Noise affects health, comfort and compliance. A busy road can disturb a neighbourhood. Likewise, a thin partition can ruin a quiet office, and a noisy plant can breach its limits. So noise evaluation puts numbers on these problems. It measures how loud noise is, how long it lasts and how well a building or material blocks it. Authorities use these results to check limits. Meanwhile, designers use them to plan quieter spaces. METS Laboratories offers noise evaluation at METS Ajman for developers, manufacturers, consultants and industrial sites across the UAE. Below, we explain our methods, the standards we follow and the results you receive.
Noise evaluation covers four areas, and each answers a different question:
Noise rises and falls from second to second, so one reading rarely tells the full story. Instead, we report several parameters. The table below explains each one.
| Parameter | What It Shows |
| LAeq | Equivalent continuous sound level |
| Lmax | Maximum sound level |
| Lmin | Minimum sound level |
| L10 | Level exceeded for 10% of the measurement time. L10 = 75 dB means the noise reached 75 dB or more for 10% of the period. |
| L50 | Median noise level. L50 = 65 dB means the noise stayed at 65 dB or higher for half the time. |
| L90 | Background noise level. L90 = 50 dB means the noise stayed above 50 dB for 90% of the time. |
Environmental noise evaluation measures sound levels outdoors. In addition, it shows how that noise affects communities, wildlife and surrounding infrastructure. We run it for these purposes:
We apply these standards:
Insulation tests show how much noise passes through a building element. We run them in the lab and on site, because each setting gives different information.
Laboratory Measurement (ISO 10140)
ISO 10140 is the international standard for laboratory measurement of sound insulation in walls, floors and ceilings. First, we measure noise that travels through a partition from a source room to a receiving room. Then we report the Weighted Sound Reduction Index (Rw), a single number that rates the partition.
Field Measurement (ISO 16283-1)
A finished building often performs differently from a lab sample. So we also follow ISO 16283-1 for field measurement of airborne sound insulation. This test shows how well walls, floors and ceilings reduce noise between real rooms. Finally, we report single-number ratings, such as the weighted standardized level difference (DnT,w).
Impact Noise (IIC)
Footsteps, dropped objects and moving furniture create impact noise. The Impact Insulation Class (IIC) test measures how well a floor assembly resists it. Moreover, builders commonly use this test on floor and ceiling systems in residential and commercial construction. We test to these methods:
Some materials arrive as small samples, so we test them in an impedance tube (ASTM E1050 / ISO 10534-2). First, the tube sends sound waves at the sample and measures the difference between the incoming and reflected sound. As a result, we can evaluate specific material properties, such as how much noise a foam, fabric or panel absorbs.
Because limits and approvals depend on data, many projects need reliable noise results:
Good noise data needs the right method for the right setting, and this is where we help:
Overall, noise evaluation turns a vague complaint into clear data. Whether you assess traffic noise or rate a partition, the right standard gives results you can compare and defend. METS Laboratories provides noise evaluation at METS Ajman, from outdoor surveys to lab insulation tests. Contact us to discuss your project.